Home > Error Code > Coleman Spa Flo Error Code

Coleman Spa Flo Error Code

Contents

Undo the union and slide it over to get access to the impeller. If it is summer logic causing the FLO message, will it return to normal operation on its own once the water temp drops? When you get the Plug error code that usually means the topside panel cord or connection is causing it. One test you can do with the pressure switch is to shut off power remove the two wires on switch and put the wires together with tape. Source

Watch QueueQueueWatch QueueQueue Remove allDisconnect The next video is startingstop Loading... With a complete retail pool store in Amesbury.

© 2014 Precision Pool Construction | 978-388-2585 | [emailprotected] Back to Top
Optimization WordPress Plugins & Solutions by W3 EDGE If the Flashing FLO message did not go away when you removed the filter then you possibly have an obstruction or blockage in the circulation system. First determine which message you are seeing. https://spacare.com/commonspasideerrorcodes.aspx

Jacuzzi Hot Tub Flo Error

FLO or three dots flahing means the swithc failed to turn on. FINAL NOTE: Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. It came and fits perfect. Nigel May 21, 2016 Reply Sean you could have an airlock that needs to be purged.

Visit Hot Tub Outpost USA. It very well could be the spa high limit sensor causing the problem. Ever since refilling the spa this fall the thermostat has not been reading correctly. Marquis Spa Error Codes It would be rare that a board would cause this but is possible and since you have eliminated everything else that causes an FLO code.

How would I know if it needed a new fuse? I read that there can be an air lock but can't find how to fix. You’re close to getting this spa fixed! useful source The cover blew off and had a lot of leaves which I suspect maybe my LF problem.

If this is the case turn the GFCI breaker off to the spa and remove your filter. Balboa Hot Tub Error Codes Before we get into what causes a flow error and how to fix it I should probably explain what a low flow actually is. I would try removing the hot tub filter first and operate pump to see if error message clears, if so I would replace the filter. So I turned breaker off for 30 minutes, took a close look at the control board, checked wiring and connection.

Hydropool Hot Tub Error Codes

Check out the tunes here Connect with Jay on Google + 33 Comments Bob Oltman October 21, 2011 at 8:06 am Hi. Calcium is what holds concrete together, it is the binder for concrete. Jacuzzi Hot Tub Flo Error YOUR KNOWLEDGE OF PRODUCTS AND THE ONLINE SERVICE HELP IS OFF THE CHART. Where Is The Flow Switch On A Hot Tub Again, "Clockwise" tightens the spring and allows the pressure switch to turn off when the pump is off.. "Counter clockwise" reduces the spring tension and allows the switch to come on

It should be a small little pump that runs 24 hours a day. this contact form Since you got a flow error code when you first started up you may have had an air lock in the pump since it was drained and refilled. NOTE: The Hi Limit Sensor is located behind a shield on the stainless heater manifold and is the smaller of the two silver bullets. I can turn it to high, and lots of water comes through, but when I turn it to low, it immediately changes to PSoL and doesn't heat. Vita Spa Error Codes

I have changed circ pumps. About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new! You need to establish normal water flow first! have a peek here Will replacing the Tecmark 4037P pressure switch fix it.

Sign in to add this video to a playlist. Sundance Hot Tub Flo Error All 3 pumps come on as normal but the circulation pump doesn't. If water is coming out like normal in low speed it may be a bad pressure switch.

If the spa will not heat and there is an error code, you may just have a pressure switch problem.

Sean May 21, 2016 Reply What if your spa is flashing FLO and I have checked the filter and that doesn't fix the problem. Usually it will be one of the sensors, or the pump not pushing enough water flow through the heater while it is on (which may give a secondary FLOW error), or later the DR was gone and temp was displayed. Flc Error Code On Hot Tub The spa runs perfect on both speeds and there is great jet action but the spa will not heat because of the FLO code.

Both are secured with black plastic nut around the gray cable. As the power is then turned on, the heater is set to a higher temperature than the water is currently set at and the unit is in Standard Mode so that These parts are easily and inexpensively replaced. Check This Out It’s an Emerald Spa, I replaced the pump about 12 months ago because of a leaky seal.

I believe I have two problems anyway. ian Ranshaw October 10, 2015 at 6:18 pm Hi. If still remains in FLO and you do have good constant water flow from pump in low speed then it may be the circuit board causing this. The pressure switch is in need of adjustment, if it stays on when the pump is off.

Working... So your spa actually has poor water flow or the system thinks it does. If so that is usually an error code for a spa temp sensor. It depends if it is flashing FLO or stays on solid.

I have done a lot of work and I am not able to see or find a blockage,,,, Derrick September 14, 2015 at 2:15 pm Thank you for taking the time Pump 1 is running with the heater like it should. It was working fine for a day and then flat lined on display, like this - - - - - I shut off power and restart it doesn't get rid of The adjustment of the pressure switch means turning the black dial clockwise to make the switch more sensitive so that the heater comes on at a lower pressure.

Do the same on the remote panel too and make sure cables to each still look good. Do not run your spa for more then 5min without a filter. An OHH reading comes from the high limit sensor on the heater, which gets too hot, usually because the circulation pump is not operating, or not pushing enough water to keep Cal Spa model 6300 Getting fault codes on my tub.